Vibration Isolation
(click here)

Test Fixtures
(click here)
_  
BASE PLATES

- OVERVIEW & EXAMPLES

- SIZES (METRIC & US)

- SURFACE ACCURACY DIN 876

- MACHINED T-SLOTS DIN 650

- ANCHORS & LEVELING

- EXAMPLES

- INSTALLATION
VIBRATION ISOLATION
FLOOR CLAMPING RAILS
SURFACE PLATES
STRAIGHTENING PLATES
BLUEING PLATES
MEASURING MACH PLATES
PLATE SUPPORTS
- SUPORT FRAMES TYPE LU
- SUPPORT FRAMES TYPE UU
SURFACE ACCURACY DIN 876 
ANGLE PLATES
- TYPE WN
- TYPE WS/WSN
- SPECIAL DESIGNS
T-SLOT TABLES
MACHINE TABLES
BOX CUBES
BOX TABLES
FORGE AND SWAGE PLATES
PARALLEL VEES
CUSTOM DESIGNS

SURFACE ACCURACY DIN 876

TOLERANCES

MACHINED T-SLOTS DIN 650

T-NUTS, BOLTS & WASHERS
T-SLOT COVERS
NON-SHRINKING GROUTS
EXAMPLES
BASE PLATE LEVELING AND ANCHORING UNITS

Leveling Unit AE 55

Leveling Unit ST 30

Leveling Unit RS 30

Leveling Unit AG 30


AE 55
Used in the majority of floor plate installations for plate loads up to 30 tons/m2. Supplied complete with ground anchor and cover plate as standard equipment.

AE 82
This element is similar to AE 55 for floor plates at machine sides, who recommend a subsequent re-leveling. The scope of supply includes foundation anchors. Made for loads between 30 and-100 to/m^2.

AES 82
Similar to AE 82 but with threaded steel insert to accommodate higher thread flank loading - used only with very high plate loads, from 100 to 200 tons/m², and above.

ST 30
For installation of plates on solid ground where low working height is required. Remove cover plate and adjust level by turning the srew.

RS 30
The RS30 Align Support is used where vibration isolation of frequencies above 7 Hz are required. The size of the isolation pad is determined by the load requirements.

AG 30
This leveling unit is particularly suitable for floor plate installations which require the whole of the underside of the plate to be flooded with grout once the desired leveling has been achieved. In this case no subsequent re-leveling would be possible. Floor plates using this unit will be provided with grouting access to each hollow section of the plate. Grouting should allow for covering the lower 10-15 mm above the bottom of the plate. The level adjusting screw and cover plate are part of the STOLLE supply.

Dynamic Force Resistant Anchor Frame for Floor Plates
Floor plates are mounted with the help of anchors imbedded into the concrete of the foundation block. An anchor frame positiones and secures the anchors in respect to the anchor holes of the floor plate (more)


Further adjustment units for special applications on request.




_For more information: E-mail: [email protected] Phone:t +1 (952) 942-6104 FAX: +1 (952) 942-6106
Copyright@2002 - 2006 CFM-ITBONA LLC. All Rights reserved
CFM-ITBONA LLC, 4282 SHORELINE DRIVE, SPRING PARK, MN 55384, USA
CFM-ITBONA HOME GOTO VIBRATION ISOLATION GOTO TEST FIXTURES GOTO STOLLE HOME